The spray foam definitely has its merits.
Spray foam under roof deck.
You may have odor problems.
Yeah you probably still breathed some of it but not as much as you will now with spray foam on the roof deck.
I ve done a lot of work in energy efficient building and design.
The biggest weak point in my opinion is that if there is a roof leak you won t find out until the wood is rotted.
Closed cell foam has been applied underside of roof decks since the late 60s early 70s and to my knowledge i have not seen or heard of a rotted substrate under and conditions closed cell foam was applied.
Instead of installing a couple layers of polyiso with staggered joints and then decking he is proposing using a product like the gaf thermacal insulated nailing base.
If you use open cell spray foam on your roof rafters you should cover the finished application with a paint or sealant that retards water vapor.
Where wood shingles or shakes.
How spray foam should be installed on the underside of the roof decking the unvented attic space is completely within the building s thermal envelope.
The movement of air into indirect conditioning of an unvented attic is a slow gradual process that will not be noticeable by occupants and typically will not put any strain on the hvac system.
By encapsulating the attic and leaving the old insulation up there that filth is in your conditioned space.
The roof currently has 4 of medium density open cell spray under the deck giving us an r value of just under 22.
But spray foam insulation used at the underside of the roof deck would need to be covered by a thermal barrier and intumescent coatings are commonly used.
No interior class i vapor retarders e g plastic sheeting are installed on the ceiling side attic floor of the.
With enough closed cell spray foam under the deck or enough rigid above the deck interior moist air can t condense if the there is no condensation you don t need drying thus no need to vent.
It would come with 3 1 2 or 4 of polyiso adhered to a 7 16 deck.
Just make sure you overdo your roof when the roof is installed.
The amount of closed cell spray foam or rigid insulation is somewhere between 20 to 50 of the r value of the overall cavity insulation depending on your climate zone.
If spray foam is used in these climates zones vapor retarder requirements apply drying to the interior is limited and a vented space may still be needed directly under the roof deck.
Going back to the moisture which develops under the underlayment if this moisture has nothing to dry it out air movement under the roof deck you have a problem and having an insulation directly under it exacerbates the problem because any moisture will expand in high heat conditions.